Skip to content

docs(debug-journal): fold the 2026-11-08..11-10 queue slice; correct the curve, PV calibration and startup-retry entries - #6239

Draft
springfall2008 wants to merge 1 commit into
mainfrom
bot/debug-journal-2026-11-17
Draft

springfall2008 wants to merge 1 commit into
mainfrom
bot/debug-journal-2026-11-17

Conversation

@springfall2008

Copy link
Copy Markdown
Owner

Automated by the /journal-update triage-bot flow: folds the first 15 queue candidates (plain filename order) into tools/debug-journal.md, re-checking each against origin/main at da2b0a5b, and corrects entries that merges since the last fold have overtaken. 111 candidates remain queued after this slice (126 before it).

Candidates folded (12)

  • 6059 (both files) — one bullet under SolaX: the two messages a Predbat report may quote (write to register 0x56 was not confirmed, stopping powercontrolmode8_trigger ... ['house_load_alt']) are solax-modbus's, not Predbat's. On Predbat not able to control invertor anymore. #6059 both house_load_alt and meter 2 were disabled in the entity registry and re-enabling them restored control; docs PR docs(solax): Mode 8 control needs House Load Alt and Meter 2 sensors enabled (#6059) #6070 (merged 0c8165c9) covers the user-facing side. Also added the Source: custom_components/...:line → upstream-tag technique to Versions, logs and attachments.
  • 6061 — appended to the History fetch bullet: the empty-store half is fixed by PR fix(history): refresh tracked history from its last check; cache empty reads #6071 (merged ab5dd9e7), with history_checked, the 30-minute recheck less a 15-minute overlap, and the tracked=False precedent. The from_time half was already recorded.
  • 6062 — new bullet under DB manager: an exception in the DB thread posts no IPC result, so the caller waits IPC_TIMEOUT (60 s); engine_accepts_from_time() is the compat-gate precedent.
  • 6069 + 6073 — two bullets under Inverter control and writes: set_charge_window/set_discharge_window in apps.yaml are dead config, the runtime gates come only from the mode select, has_time_window is unread, and the charge/discharge midnight-disable writers. Rewrote the candidate's conclusion: on current main the service/immediate paths are gated on set_soc_enable, not the window flags, so Control SOC only does stop the window writes while still driving a script-controlled inverter (except a set_read_only/mode reset). Added the /debug_apps_live attachment technique to Replays and debug dumps.
  • 6075 — sharpened the existing {power} bullet: since PR Fold balance_inverters into execute: one source of inverter rate writes #5149 the rate is written by apply_rate_intent() after adjust_*_immediate() builds the payload, so the previous cycle's rate is sent; PR fix: send this cycle's planned rate as {power} to service-driven inverters (#3311, #5252) #5373 is still open (checked today).
  • 6076 — new bullet under GE Cloud. Corrected the candidate: on current main charger_control_tick() sits inside the 300 s STATUS_POLL_SECONDS block as well, so the symptom is a window boundary acted on up to ~5 minutes late on an uptime cadence, not a decision made on stale data.
  • 6083 — new bullet under Minute data: the near-midnight reset test uses the history stamp's UTC clock; probe-verified.
  • 6084 — new bullet under Minute data: get_from_incrementing() wraps a negative index by +24 h, in fetch.py, load_ml_component.py and predheat.py.
  • 6087 + 6088 — new bullet under Reading the code for the template slug group (and the specific template guards, not a general template test), plus a bullet under Solis for solis_modbus battery polarity (plain Battery Power is unsigned, the sign is register 33135; map battery_power_net, no battery_power_invert). PR Updates to solis_local.yaml #6088 is open and main still maps plain _battery_power; marked as verified against the integration source, not hardware.

Candidates dropped (3)

Existing entries corrected (with the merge that invalidated them)

Consolidation and file size

  • The two stale sections above were rewritten rather than patched, replacing obsolete narrative with the current mechanism.
  • The file is now 236 KB (226 KB before this fold) and remains above the ~150 KB guidance. The growth is new mechanism detail, not duplicated bullets; the largest remaining areas are Octopus and Plan: charging and holding. I have not attempted a wholesale compaction here — putting unverified rewrites of those dense sections into the file would be worse than its size.
  • Checked against git log --since="2 weeks ago" origin/main and each merged PR named above.

Verification

  • ./run_pre_commit: every hook passes (cspell, markdownlint, ruff, black, and the repo's own test hooks). The quick suite fails only in web_pv_calibration_chart (t10 next scan), which fails on clean main from today's date; this change is documentation only and nothing reads it at test time.

…the curve, PV calibration and startup-retry entries

- fold 12 of the 15 queued candidates, in nine bullets; drop 3 already covered or fixed (6056/#6057, 6072, 6074)
- rewrite the charge/discharge curve section for the learned SoC x temperature rate grid (#6212/#6227/#6189)
- correct PV calibration to the 28-day evidence store (#6231/#6233), the fatal-error latch (PR #5766 merged) and the balancer (#6194)
- record the hardcoded-date failure in test_web_pv_calibration_chart seen on main from 17 Nov

Co-Authored-By: Claude Code <noreply@anthropic.com>

This branch has not been deployed

No deployments
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant